MANTIS RFID SCAN

Lo-Fi Wireframes • Box Layout

Workflow Diagram

App Launch
Login
Select Project
Select Workflow
Fabricated Spools
  1. Fab In Progress
  2. Fab Complete
  3. Shipped (BOL)
  4. Onsite (Geo)
  5. Install In Progress
  6. Install Complete
  7. CCO Complete
Field Run Piping
  1. Print Label
  2. % Complete (5%)
  3. Complete (LF)
  4. CCO Complete
Inline Devices
Instrumentation (7)
  1. Onsite
  2. Calibrated
  3. Installed
  4. Tubing
  5. Electrical
  6. Complete
  7. CCO

Manual Valves (3)
  1. Onsite
  2. Complete
  3. CCO

Control Valves (7)
  1. Onsite
  2. Calibrated
  3. Installed
  4. Tubing
  5. Electrical
  6. Complete
  7. CCO

Core Screens

MANTIS
Username
email@company.com
Password
••••••••
SIGN IN
Forgot Password?
Login
Select Project
Search...
Waco Paper Mill
Waco, TX • 234 items
Macon Pulp HVAC
Macon, GA • 89 items
Waco Hot Water
Waco, TX • 156 items
Project Selection
Waco Paper Mill
Fabricated Spools
7-stage tracking
Field Run Piping
On-site installation
Inline Devices
Valves & Instrumentation
Workflow Selection
Scan RFID
[ ]
Point scanner at RFID tag
or press trigger
📷 Camera
✎ Manual
Scan Ready

Fabricated Spools (7 Stages)

1
2
3
4
5
6
7
Spool Details
SP-2024-0847 Fab In Progress
Line Number
4"-STM-1234-A1
Service
150# Steam
Size
4" NPS
1
2
3
4
5
6
7
SCAN TO UPDATE
Stage 1: Fab In Progress
Fab Complete
✓ RFID Scanned
SP-2024-0847 Complete
Checklist
100% Complete
Final QC Passed
RFID Label Applied
RFID Scanned
2
3
4
5
6
7
PROCEED TO SHIPPING →
Stage 2: Fab Complete
Ship Spool
SP-2024-0847 Ready to Ship
Bill of Lading #
BOL-2024-1234
Carrier
Select Carrier ▼
Truck #
TRK-5589
Scanned Items (3)
SP-2024-0847
SP-2024-0848
SP-2024-0849
SCAN DEPARTURE
Stage 3: Shipped (BOL)
Receive Delivery
BOL-2024-1234 Delivered
📍 Geo-Tagged Location
31.5493° N, 97.1467° W
Jan 15, 2026 • 2:34 PM
Unload Verification
SP-2024-0847
SP-2024-0848
SP-2024-0849
⚠ REPORT DISCREPANCY
✓ CONFIRM RECEIPT
Stage 4: Onsite (Geo-tag)
Installation
SP-2024-0847 Installing
Location
Boiler House, Level 2
Crew
Steam Crew A
📍 Movement Tracking
2:34 PM → Pipe Yard
3:15 PM → Boiler House
5
6
7
SCAN: INSTALL COMPLETE
Stage 5: Install In Progress
Install Complete
✓ Installation Verified
SP-2024-0847 Installed
Final Location
Boiler House, L2-B7
Installed By
J. Rodriguez
Completed
Jan 15, 4:22 PM
6
7
PROCEED TO CCO →
Stage 6: Install Complete
CCO Completion
SP-2024-0847 CCO Review
CCO Complete ✓
All work verified
Punch Item Required
Issue needs resolution
7
✓ COMPLETE CCO
Stage 7: CCO Complete

Field Run Piping

Field Run Piping
FR-2024-0156 New
Line Number
2"-HW-5678-B3
Service
Hot Water Return
Estimated LF
150 LF
🖨
1 label per line
🖨 PRINT RFID LABEL
◎ SCAN EXISTING
Print Label On-site
Update Progress
FR-2024-0156 In Progress
Percent Complete
45%
45% ▼
5% increments
SCAN TO UPDATE
Progress (5% increments)
Complete Line
✓ 100% Complete
FR-2024-0156 Complete
Actual Quantity Installed
147
LF
Variance: -3 LF (2%)
✓ CONFIRM COMPLETE
Complete (Actual LF)
CCO Review
FR-2024-0156 CCO Review
Estimated 150 LF
Actual 147 LF
Variance -2%
CCO Complete ✓
Punch Item
SCAN TO COMPLETE
CCO Complete

Inline Devices

Instrumentation
FT-1234 In Progress
Onsite
Calibrated Yes
Installed (watertight)
Tubing Installed
Electrical Complete
Complete
CCO Complete
SCAN NEXT STAGE
Instrumentation (7 stages)
Calibration
FT-1234 Calibration
Calibration Required?
Optional per project
Yes - Calibrated
No - Not Required
N/A
CONFIRM →
Calibration (Optional)
Manual Valve
HV-5678 In Progress
Onsite ◎/✓
Complete (Bolts Torqued) ◎/✓
CCO Complete ◎/✓
◎ Scan
✓ Mark
Manual Valves (3 stages)
Control Valve
FCV-9012 In Progress
Onsite
Calibrated
Installed
Tubing
Electrical
Complete (Torqued)
CCO Complete
SCAN / ✓ COMPLETE
Control Valves (7 stages)

Shared Components

CCO
Punch Item ✕
Issue Description *
Steam trap needs...
Hours to Resolve *
4
hours
Photo *
📷 Tap to add
Cancel
Submit
Punch Item Dialog
Punch Items
PI-0023 Open
Steam trap replacement
Est: 4 hrs • 📷 1 photo
◎ Scan
✓ Mark
PI-0022 ✓ Done
Insulation support added
Resolved: Jan 14
Punch Item List
Discrepancy Report
⚠ BOL Mismatch
BOL-2024-1234
Expected 5
Received 4
Missing:
SP-2024-0850 - Not Scanned
📍 31.5493° N, 97.1467° W
Jan 15, 2:34 PM
Notes
SUBMIT REPORT
Discrepancy Report
Complete!
SP-2024-0847
CCO Verified
7 of 7
Stages
0
Punch
SCAN NEXT ITEM
RETURN TO DASHBOARD
Success State

Design Notes: